CABLE
PERFORMANCE PARAMETERS:
Below are summaries of the key points for the current Category
specifications. Although still under development with the IEC, Category
7 is listed as there is confusion with so called “levels”
programs.
Category 5e
compliant cabling systems are the standard
installation today. Although the category
5e system has an upper frequency limit
of 100 MHz minimum, (category 5 is 100
MHz also) this UTP system will demonstrate
significant enhancements over category
5 in return loss, power sum and Equal
Level Far-End Cross Talk (ELFEXT) enabling
the support of Gigabit Ethernet.
Category 6
cabling systems offer enhanced performance
over 5e systems. This cabling system available
in UTP or ScTP versions will provide an
upper frequency limit of 250 MHz minimum.
This bandwidth capacity with other performance
enhancements make it an ideal solution
for the heavily technology dependant enterprise
that may require the additional margin
provided. There is a significant premium
paid for a category 6 solution, typically
between 15% and 20% of the overall installation
cost of a category 5e system.
Category 7
cabling systems are not currently under
development within TIA/EIA. The standard
is under development within the IEC. This
shielded cabling system will provide an
upper frequency limit of 600 MHz and utilizes
a new connector/jack design. Systems are
available today which comply with the
current draft of this standard.
|
TIA/EIA-568-B.2
4 UTP Performance Specifications |
 |
|
INSERTION LOSS |
Frequency
(MHz) |
Cat
3
(db) |
Cat
5e
(db) |
Cat
6
(db) |
0.77 |
2.2 |
1.8 |
1.8 |
1.00 |
2.6 |
2.0 |
2.0 |
4.00 |
5.6 |
4.1 |
3.8 |
8.00 |
8.5 |
5.8 |
5.3 |
10.00 |
9.7 |
6.5 |
6.0 |
16.00 |
13.1 |
8.2 |
7.6 |
20.00 |
- |
9.3 |
8.5 |
25.00 |
- |
10.4 |
9.5 |
31.25 |
- |
11.7 |
10.7 |
62.50 |
- |
17.0 |
15.4 |
100.00 |
- |
22.0 |
19.8 |
200.00 |
- |
- |
29.0 |
250.00 |
- |
- |
32.8 |
 |
|
RETURN LOSS |
Frequency
(MHz) |
Cat
3
(db) |
Cat
5e
(db) |
Cat
6
(db) |
0.77 |
- |
17.0 |
- |
1.00 |
- |
17.0 |
20.0 |
4.00 |
- |
17.0 |
23.0 |
8.00 |
- |
17.0 |
24.5 |
10.00 |
- |
17.0 |
25.0 |
16.00 |
- |
17.0 |
25.0 |
20.00 |
- |
17.0 |
25.0 |
25.00 |
- |
16.0 |
24.3 |
31.25 |
- |
15.1 |
23.6 |
62.50 |
- |
12.1 |
21.5 |
100.00 |
- |
10.0 |
20.1 |
200.00 |
- |
- |
18.0 |
250.00 |
- |
- |
17.3 |
 |
|
NEXT LOSS |
Frequency
(MHz) |
Cat
3
(db) |
Cat
5e
(db) |
Cat
6
(db) |
0.77 |
43.0 |
67.0 |
76.0 |
1.00 |
41.3 |
65.3 |
74.3 |
4.00 |
32.3 |
56.3 |
65.3 |
8.00 |
27.8 |
51.8 |
60.8 |
10.00 |
26.3 |
50.3 |
59.3 |
16.00 |
23.2 |
47.2 |
56.3 |
20.00 |
- |
45.8 |
54.8 |
25.00 |
- |
44.3 |
53.3 |
31.25 |
- |
42.9 |
51.9 |
62.50 |
- |
38.4 |
47.4 |
100.00 |
- |
35.3 |
44.3 |
200.00 |
- |
- |
39.8 |
250.00 |
- |
- |
38.3 |
|
|